4.7 Article

Confirmation of organic micropollutants detected in environmental samples by liquid chromatography tandem mass spectrometry:: Achievements and pitfalls

期刊

TRAC-TRENDS IN ANALYTICAL CHEMISTRY
卷 25, 期 10, 页码 1030-1042

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.trac.2006.06.012

关键词

antibiotic; confirmation; environmental sample; liquid chromatography; mass spectrometry; organic micropollutant; pesticide

向作者/读者索取更多资源

Different approaches to the confirmation of pesticides and antibiotics detected in environmental waters have been evaluated using liquid chromatography (LC) hyphenated to mass spectrometry (MS) - both triple quadrupole (QqQ) and hybrid quadrupole-time-of-flight (Q-TOF) analyzers. After analyzing more than 100 groundwater and surface-water samples, we discuss in this article the main achievements and pitfalls of LGMS in confirmation of positive findings. The acquisition of, at least, two specific Selected Reaction Monitoring (SRM) transitions for each analyte when using LC-tandem MS (LC-MS2) QqQ was found to be an efficient and simple way of achieving safe confirmation, while the use of only one transition would have resulted in some false positives in the samples analyzed. The use of non-specific transitions, such as those involving the loss of water, might sporadically result in false positive findings even after acquiring two transitions, as the probability of finding interferences sharing the same transition increases. Moreover, some false negatives might be reported when acquiring two transitions when one of them is shared by an interferent, as it would affect the experimental ion-abundance ratio. This possibility is more likely to occur at sub-ppb analyte concentrations than at higher concentrations. For this reason, we found that the acquisition of the highest number of available transitions was an efficient way to improve reliability in the confirmation process. The use of Q-TOF-MS can provide an ultimate, unequivocal confirmation of positive findings, due to its inherent advantages of accurate mass and acquisition of complete product-ion spectra. However, false negatives could be reported if a co-eluting isobaric interference was present. In that case, we found that a more efficient chromatographic separation was the best way to improve the confirmation process. The lower sensitivity of Q-TOF in comparison to QqQ can be one drawback of this approach, which can hamper the confirmation at very low analyte concentration levels. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据