4.7 Article

Parallel generation and detection of superoxide and hydrogen peroxide in a fluidic chip

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 119, 期 1, 页码 118-126

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2005.11.062

关键词

biosensor; cytochrome c; flow system; reactive oxygen species; antioxidant

向作者/读者索取更多资源

A fluidic chip system was developed, which combines a stable generation of superoxide radicals and hydrogen peroxide with their sensorial detection. The generation of both reactive oxygen species was achieved by immobilization of xanthine oxidase on controlled pore glass in a reaction chamber. Antioxidants can be introduced into the fluidic chip system by means of mixing chamber. The detection of both species is based on the amperometric principle using a biosensor chip with two working electrodes. As sensing protein for both electrodes cytochrome c was used. The novel system was designed for the quantification of the antioxidant efficiency of different potential scavengers of the respective reactive species in an aqueous medium. Several model antioxidants such as ascorbic acid or catalase have been tested under flow conditions. (c) 2005 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据