期刊
SHOCK WAVES
卷 16, 期 2, 页码 157-165出版社
SPRINGER
DOI: 10.1007/s00193-006-0058-6
关键词
tailoring; shock tube; reflected shock; chemical kinetics
类别
To study combustion chemistry at low temperatures in a shock tube, it is of great importance to increase experimental test times, and this can be done by tailoring the interface between the driver and driven gases. Using unconventional driver-gas tailoring with the assistance of tailoring curves, shock-tube test times were increased from 1 to 15 ms for reflected-shock temperatures below 1,000 K. Provided in this paper is the introduction of tailoring curves, produced from a one-dimensional perfect gas model for a wide range of driver gases and the production and demonstration of successful driver mixtures containing helium combined with either propane or carbon dioxide. The He/CO2 and He/C3H8 driver mixtures provide a unique way to produce a tailored interface and, hence, longer test times, when facility modification is not an option. The tailoring curves can be used to guide future applications of this technique to other configurations. Nonreacting validation experiments using driver mixtures identified from the tailoring curves were performed over a range of reflected-shock temperatures from approximately 800 to 1,400 K, and some examples of ignition-time experiments that could not have otherwise been erformed are presented.