4.4 Article

Modelling the normal retinal nerve fibre layer thickness as measured by Stratus optical coherence tomography

期刊

出版社

SPRINGER
DOI: 10.1007/s00417-006-0372-9

关键词

nerve fibre layer thickness; optical coherence tomography; healthy subjects; age; refractive error; lens; optic disc

向作者/读者索取更多资源

Background: The variation in retinal nerve fibre layer thickness (RNFLT) as measured by Stratus optical coherence tomography (OCT) in healthy subjects may be reduced when the effect on RNFLT measurements of factors other than disease is corrected for, and this may improve the diagnostic accuracy in glaucoma. With this perspective we evaluated the isolated and combined effects of factors potentially affecting the Stratus OCT RNFLT measurements in healthy subjects. Methods: We included 178 healthy eyes of 178 subjects between 20 and 80 years of age. Participants underwent an extensive eye examination. Stratus OCT RNFLT was measured by three standard protocols, two with high and one with standard image resolution. Effects on RNFLT of age, gender, refractive error, axial length, lens nuclear colour and opalescence, intra-ocular pressure (IOP), and optic disc size were examined by univariate and multivariate analyses. Results: Age, refractive error, axial length, and lens nuclear colour and opalescence affected RNFLT in univariate analyses, whereas gender, IOP, and optic disc size had no significant effect. In multivariate analyses only age in combination with refractive error, or with axial length, was significant and explained 14.7-17.6% (R-2 stop) of the total variation of RNFLT, approximately 50% more than age alone. RNFLT decreased by 2.6-2.9 mu m per increasing decade of age and increased by 1.5-1.8 mu m per more positive diopter of spherical equivalent using full-circle measurements of the three standard protocols. These effects varied between measurement sectors. Conclusions: RNFLT as measured by Stratus OCT standard protocols was significantly affected by age and refractive status. The effect on global RNFLT of a difference in refractive error of 10 diopters corresponded to the effect of a difference in age of 60 years. Theoretically, the effect of refractive status may be explained by artefacts of RNFLT measurement circle placement. The results suggest that the diagnostic accuracy of Stratus OCT may be improved by considering refractive status in addition to age when RNFLT is measured. For this purpose spherical equivalent seems as effective as axial length.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据