期刊
MICROCHIMICA ACTA
卷 156, 期 3-4, 页码 263-269出版社
SPRINGER WIEN
DOI: 10.1007/s00604-006-0642-6
关键词
silver; cadmium; geological and environmental samples; ICP-MS
The suitability of three different digestion procedures has been evaluated with regard to the quantitative determination of trace amounts of silver and cadmium in geological and environmental samples. Procedure A: extraction with aqua regia in an open vessel system; Procedure B: extraction with aqua regia in a closed pressurized vessel system; Procedure C: digestion with HF + HNO3 in a closed pressurized vessel system. It was found that procedure A represented an effective way of extracting analytes from different types of geological samples while the effect of extracting interfering metals is low. Because it is interference-free, poses a low risk of contamination and is time-saving, sample treatment procedure A was preferred. For this digestion procedure, a series of Chinese geological reference materials was determined by ICP-MS, the results of which were found to be in reasonable agreement with the certified values.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐