4.7 Article

Indoor microclimate, ozone and nitrogen oxides in two medieval churches in Cyprus

期刊

ATMOSPHERIC ENVIRONMENT
卷 40, 期 39, 页码 7457-7466

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.atmosenv.2006.07.015

关键词

indoor air quality; church; indoor climate; ozone; nitrogen oxides

向作者/读者索取更多资源

A number of indoor atmosphere parameters that may affect the preservation of artefacts in two churches in Cyprus, were studied. Temperature, relative humidity (RH), total ultra-violet and total solar radiation, that were continuously recorded during two campaigns (summer and winter), exhibited large diurnal and seasonal variations. Indoor concentrations of nitrogen oxides, determined at the same periods, also exhibited diurnal dependence on air exchange rate (AER) and on their indoor sources from the burning of candies and oil lamps. Indoor concentrations of ozone exhibited dependence on the AER and on the concentration of other indoor pollutants. On a large number of occasions these concentrations exceeded the proposed air quality standards for the preservation of works of art in both churches. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据