4.7 Article

Fabrication of a highly selective and sensitive Gd(III)-PVC membrane sensor based on N-(2-pyridyl)-N′-(4-nitrophenyl)thiourea

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 120, 期 2, 页码 487-493

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2006.03.001

关键词

Gd(III) sensor; potentiometry; PVC; N-(2-pyridyl)-N '-(4-nitrophenyl)thiourea (PyTu4NO(2))

向作者/读者索取更多资源

In this work we report the development of a highly selective and sensitive Gd(III) membrane based on N-(2-pyridyl)-N'-(4-nitrophenyl)thiourea (PyTu4NO(2)) as an excellent neutral ion carrier, The Gd(III) sensor exhibits a Nernstian slope of 19.95 +/- 0.3 mV per decade over the concentration range of 3.0 x 10(-7) to 1.0 x 10(-1) M, and a detection limit of 3.0 x 10-7 M of Gd(III) ions. The potentiometric response of the sensor is independent of the solution pH in the range of 4.0-9.0. It manifests advantages of low detection limit, fast response time (similar to 10 s), and most significantly, very good selectivity with respect to a number of lanthanide ions (La, Ce, Sm, and Eu ions). It can be used at least for a period of 8 weeks without any significant divergences in its potential response. To assess its analytical applicability the proposed Gd(HI) sensor was successfully applied as an indicator electrode in the titration of Gd(III) ion solutions with EDTA and for the determination of the fluoride ion in two mouth wash preparations. It was also used for the direct monitoring of Gd(III) ions in binary mixtures. (c) 2006 Elsevier B.V. All rights reserved.