4.5 Article

Is serum troponin T a useful marker of myocardial damage in newborn infants with perinatal asphyxia?

期刊

ACTA PAEDIATRICA
卷 96, 期 2, 页码 181-184

出版社

BLACKWELL PUBLISHING
DOI: 10.1111/j.1651-2227.2007.00104.x

关键词

cardiac troponin T; echocardiography; myocardial ischaemia; perinatal asphyxia

向作者/读者索取更多资源

Aim: To assess the correlation of echocardiographic signs of myocardial damage to serum cardiac troponin T (cTnT) concentrations in newborn infants with perinatal asphyxia. Methods: Electocardiograms (ECG) and echocardiograms (Echo) were obtained during the first 24 h of life from 29 asphyxiated and 30 control infants and correlated with cTnT concentrations. The echocardiographic parameters included systolic ventricular performance, preload, afterload, diastolic function, stroke volume (SV), left ventricular output (LVO), hyperechogenity of the papillary muscles and insufficiency of the atrioventricular valves. Results: LVO and SV were lower but CTnT were significantly higher in asphyxiated than in control infants: 0.15 (010-0.23) vs. 0.05 (0.02-0.13), p < 0.001). Asphyxiated infants with signs of myocardial damage were associated with significantly higher cTnT than those without, 0.20 (0.11-0.28) and 0.11 (0.05-0.14 ug/L), p = 0.04. Conclusion: Cardiac troponin may prove to be valuable in evaluating myocardial damage in birth asphyxia. However, the degree of prematurity may complicate the assessment.