4.4 Article

The localisation and micro-mapping of copper and other trace elements in breast tumours using a synchrotron micro-XRF system

期刊

APPLIED RADIATION AND ISOTOPES
卷 65, 期 2, 页码 183-188

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.apradiso.2006.08.013

关键词

X-ray fluorescence (XRF); synchrotron radiation; micro-XRF; breast cancer; trace elements

向作者/读者索取更多资源

Trace elements have critical roles in cancer biology. The quantity and distribution of the elements Cl, Ca, K, P, S, Ti, Fe, Cu and Zn in samples of primary breast cancer have been assessed. The samples were formalin fixed tissue specimens formatted as microarrays of cores 1.0 mm diameter and 10 mu m thick each. The data were obtained using a synchrotron X-ray fluorescence microprobe system. The spatial resolution of elemental maps was approximately 20 mu m. Maps were compared with light transmission images of the samples and then the images were stained for cancer. The synchrotron system proved successful in producing data that could be mapped into high-resolution images where clear structure could be identified. Correlation of these distributions with the concentrations of cancer cells was achieved in some samples. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据