4.3 Article

Bond failure with a no-mix adhesive system

期刊

ANGLE ORTHODONTIST
卷 78, 期 3, 页码 545-548

出版社

E H ANGLE EDUCATION RESEARCH FOUNDATION, INC
DOI: 10.2319/010707-6.1

关键词

bond failure; no-mix adhesive; bracket failure

向作者/读者索取更多资源

Objective: To determine the bond failure pattern and time to first bond failure at an orthodontic clinic. Materials and Methods: The study included 63 subjects meeting the study criteria. A total of 1074 brackets (Roth prescription 0.022 slot) were bonded to incisors, canines, and premolars using a no-mix adhesive (Unite, 3M Unitek). The survival and failure rates of the brackets were evaluated by tooth position in the dental arch, sagittal occlusal relationship, and gender of the patients. Overall bracket survival rates were estimated using the Kaplan-Meier test. Results: The total percentage of bond failure was 17.87%. The mean survival time for the sample was 235 days (SE = 32.27 days). Significantly higher failure rates were observed for posterior than anterior teeth (P <.05) and in the Class II division 2 malocclusion group than other malocclusion groups (P <.05). No difference was observed between dental arches or genders. However, in terms of survival time, the difference was marginally significant for gender (P = .051) Conclusion: For 1074 brackets bonded with a no-mix adhesive system in 63 patients, the mean time until first bracket failure was 235 days. The overall failure rate of brackets was 17.87%.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据