IgG classification of anti-PF4/heparin antibodies to identify patients with heparin-induced thrombocytopenia during mechanical circulatory support

期刊

JOURNAL OF THROMBOSIS AND HAEMOSTASIS
卷 5, 期 2, 页码 235-241

出版社

WILEY
DOI: 10.1111/j.1538-7836.2007.02295.x

关键词

circulatory assist devices; heparin-induced thrombocytopenia; thrombosis

向作者/读者索取更多资源

Commercial immunoassays frequently detect anti-PF4/heparin antibodies during mechanical circulatory support (MCS), but only a small minority of patients develops heparin-induced thrombocytopenia (HIT). Whereas platelet functional tests can distinguish between platelet-activating and non-platelet-activating antibodies, commercial PF4-dependent immunoassays do not. Between 2003 and 2004, 113 patients were placed on MCS. Blood samples were obtained on postimplant day 5-7 for analyses by antibody assays and the functional heparin-induced platelet activation (HIPA) assay. Three distinct groups of patient sera were identified: platelet-activating anti-PF4/heparin antibodies (n=10), non-platelet-activating anti-PF4/heparin antibodies (n=53), and anti-PF4/heparin antibody negative (n=50). Patients with platelet-activating antibodies had the highest risk for thromboembolic events (P < 0.005), whereas those with non-platelet-activating antibodies did not differ from antibody negative patients (P=0.369). The enzyme-immunoassay and column agglutination assays, which cover all immunoglobulin classes, demonstrated adequate sensitivity and negative predictive value; yet, both lacked specificity with respect to the platelet-activating antibodies. If all antibody positive patients were further classified by an IgG-specific anti-PF4/heparin enzyme-immuno assay, specificity for platelet-activating antibodies increased. Whereas IgG-specific optical density (OD) values below 1.0 were likely for non-platelet-activating anti-PF4/heparin antibodies, higher values were progressively predictive for pathogenic platelet activation. The probability of the development of clinical HIT also increased steeply. In conclusion, platelet-activating anti-PF4/heparin antibodies are relatively common (about 9%) in patients on MCS and are associated with significantly higher thrombotic event rates. Low IgG-specific OD values (< 1.0) in the enzyme-immunoassay indicate low likelihood for the presence of platelet-activating antibodies. These results justify further validation so that anticoagulation during MCS becomes safer and adequate.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据