4.7 Article

Use of SVET and SECM to study the galvanic corrosion of an-iron-zinc cell

期刊

CORROSION SCIENCE
卷 49, 期 2, 页码 726-739

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2006.04.021

关键词

iron; zinc; SVET; SECM; galvanic couple

向作者/读者索取更多资源

The work makes use of the scanning vibrating electrode technique (SVET) and the scanning electrochemical microscope (SECM) to investigate microscopic aspects of the electrochemical reactions that occur in an iron-zinc galvanic couple immersed in aqueous sodium chloride solution. Detection of the corrosion processes was made by sensing the phenomena occurring in solution. The SVET provided information on the distribution of ionic currents arising from the metal surface, whereas the SECM measured the concentration of chemical species relevant to the corrosion processes. The two techniques had comparable sensitivity for the corrosion of iron but significant differences were observed concerning the detection of corrosion of zinc. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据