期刊
CORROSION SCIENCE
卷 49, 期 2, 页码 726-739出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2006.04.021
关键词
iron; zinc; SVET; SECM; galvanic couple
The work makes use of the scanning vibrating electrode technique (SVET) and the scanning electrochemical microscope (SECM) to investigate microscopic aspects of the electrochemical reactions that occur in an iron-zinc galvanic couple immersed in aqueous sodium chloride solution. Detection of the corrosion processes was made by sensing the phenomena occurring in solution. The SVET provided information on the distribution of ionic currents arising from the metal surface, whereas the SECM measured the concentration of chemical species relevant to the corrosion processes. The two techniques had comparable sensitivity for the corrosion of iron but significant differences were observed concerning the detection of corrosion of zinc. (c) 2006 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐