4.6 Article

Use of experimental design in the optimization of stir bar sorptive extraction for the determination of polybrominated diphenyl ethers in environmental matrices

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1141, 期 2, 页码 259-270

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2006.12.011

关键词

polybrominated diphenyl ethers; factorial design; stir bar sorptive extraction; liquid desorption; large volume injection; capillary GC-MS; environmental matrices; printed board circuits

向作者/读者索取更多资源

Stir bar sorptive extraction and liquid desorption (LD) followed by large volume injection and capillary gas chromatography coupled to mass spectrometry (SBSE-LD-LVI-GC-MS), had been applied for the determination of ultra-traces of eleven polybrominated diphenylethers (PBDEs), from tetra to nona congeners (BDE-47, BDE-100, BDE-99, BDE-85, BDE-154, BDE-153, BDE-183, BDE-197, BDE-196, BDE-207 and BDE-206), in environmental matrices. Instrumental calibration under the selected-ion monitoring (SIM) mode acquisition and parameters that could affect the SBSE-LD efficiency are fully discussed. A complete randomized factorial design was established for the first time to optimize the main experimental parameters that affecting the SBSE-LD efficiency, including decisive interactions, which provides a more realistic picture of the sampling process. The analysis of variance (ANOVA) was the statistical method used to analyze data. From the data obtained, it can be emphasized that experimental parameters such as extraction time (240 min), agitation speed (1250 rpm), methanol content (40%) and desorption conditions (acetonitrile, 15 min), were the best analytical compromise for the simultaneous determination between tetra and nona congeners in aqueous media. A remarkable recovery (65.6 - 116.9%) and repeatability (< 12.1%) were attained, whilst the experimental data allowed very good agreement with predict theoretical equilibrium described by the octanol-water partition coefficients (K-PDMS/W K-O/W), with the exception of nona congeners since slightly lower yields were measured. Furthermore, excellent linear dynamic ranges from 0.01 to 14.0 mu g/L (r(2) > 0.9917) and low detection limits (0.3 - 203.4 ng/L) were also achieved for the eleven congeners studied. The proposed methodology was applied for the determination of ultra-trace levels of PBDEs in waste water, sediments and printed board circuit matrices by the standard addition approach, showing to be reliable, sensitive and having a low sample amount requirement in compliance with the international regulatory bodies. (c) 2006 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据