4.6 Article

Exhaled breath condensate pH stanclardised for CO2 partial pressure

期刊

EUROPEAN RESPIRATORY JOURNAL
卷 29, 期 3, 页码 496-501

出版社

EUROPEAN RESPIRATORY SOC JOURNALS LTD
DOI: 10.1183/09031936.00084006

关键词

airway biology; airway inflammation; breath test; exhaled biomarkers; exhaled breath condensate

向作者/读者索取更多资源

Exhaled breath condensate (EBC) pH is considered to reflect the acid-base balance of the airways. Current pH measurements do not take into account the effect Of CO2. The aim of the present study was to determine the effect of condensate CO2 partial pressure on pH and to provide a more precise mode of EBC pH determination. Condensate pH and CO2 partial pressure were measured in parallel from 12 healthy volunteers and 12 asthmatics using a blood gas analyser in neat, argon de-aerated and CO2-loaded samples. The regression analysis was used to test the relationship between pH and CO2, and to calculate the pH at a CO2 level of 5.33 kPa (physiological alveolar CO2 partial pressure). Reproducibility of different pH readings was compared using the Bland-Altman test. Condensate CO2 concentration was variable both in neat and argon de-aerated samples. There was a close negative logarithmic relationship between CO2 and pH. Calculation of pH at a CO2 level of 5.33 kPa provided reproducibility approximately six times as good as that of the currently used measurements. Condensate CO2 partial pressure influences pH measurements. Determination of pH at a standard CO2 level provides the most reproducible condensate pH values to date.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据