期刊
JOURNAL OF APPLIED POLYMER SCIENCE
卷 103, 期 5, 页码 3271-3277出版社
WILEY
DOI: 10.1002/app.25489
关键词
electropolymerization; carmine; 4-nitrophenol; sensor
4-Nitrophenol (4-NP) has been determined with voltammetric technique based on a novel sensor fabricated by electropolymerization of carmine on a glassy carbon electrode (GCE). An obvious reduction peak located at about -0.700 V and a couple of redox peaks that were not well-defined were observed in the potential range of -1.00 to 0.600 V. Compared with its voltammetric behavior on a bare GCE, the reduction peak potential shifted positively and the peak current increased significantly. All experimental parameters were optimized and linear sweep voltammetry was proposed for its determination. In the optimal conditions, the reduction peak current was proportional to the 4-NP concentration over the concentration range from 5.00 x 10(-8) to 1.00 x 10(-5) mol L-1, and the detection limit was 1.00 x 10(-8) mol L-1 after 200 s of accumulation. The high sensitivity and selectivity of the sensor was demonstrated by its practical application for the determination of trace amounts of 4-NP in lake water. (c) 2006 Wiley Periodicals, Inc.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐