4.7 Article Proceedings Paper

Quantitation of 17β-nandrolone metabolites in boar and horse urine by gas chromatography-mass spectrometry

期刊

ANALYTICA CHIMICA ACTA
卷 586, 期 1-2, 页码 184-195

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2006.08.033

关键词

boar; horse; urine; 17 beta-nandrolone metabolites; gas chromatography/mass spectrometry

向作者/读者索取更多资源

A method to quantify metabolites of 17 beta-nandrolone (17 beta N) in boar and horse urine has been optimized and validated. Metabolites excreted in free form were extracted at pH 9.5 with tert-butylmethylether. The aqueous phases were applied to Sep Pak Cis cartridges and conjugated steroids were eluted with methanol. After evaporation to dryness, either enzymatic hydrolysis with beta-glucuronidase from Escherichia coli or solvolysis with a mixture of ethylacetate: methanol: concentrated sulphuric acid were applied to the extract. Deconjugated steroids were then extracted at alkaline pH with tert-butylmethylether. The dried organic extracts were derivatized with MSTFA:NH4I:2-mercaptoethanol to obtain the TMS derivatives, and were subjected to analysis by gas chromatography mass spectrometry (GC/MS). The procedure was validated in boar and horse urine for the following metabolites: norandrosterone, noretiocholanolone, norepiandrosterone, 5 beta-estran-3 alpha, 17 beta-diol, 5 alpha-estran-3 beta, 17 beta-diol, 5 alpha-estran-3 beta, 17 alpha-diol, 17 alpha-nandrolone, 17 beta N, 5(10)-estrene-3 alpha, 17 alpha-diol, 17 alpha-estradiol and 17 beta-estradiol in the different metabolic fractions. Extraction recoveries were higher than 90% for all analytes in the free fraction, and better than 80% in the glucuronide and sulphate fractions, except for 17 beta-estradiol in the glucuronide fraction (74%), and 5 alpha-estran-3 beta, 17 alpha-diol and 17 beta N in the sulphate fraction (close to 70%). Limits of quantitation ranged from 0.05 to 2.1 ng mL(-1) in the free fraction, from 0.3 to 1.7 ng mL(-1) in the glucuronide fraction, and from 0.2 to 2.6 ng mL(-1) in the sulphate fraction. Intra- and inter-assay values for precision, measured as relative standard deviation, and accuracy, measured as relative standard error, were below 15% for most of the analytes and below 25%, for the rest of analytes. The method was applied to the analysis of urine samples collected after administration of 17 beta N laureate to boars and horses, and its suitability for the quantitation of the metabolites in the three fractions has been demonstrated. (c) 2006 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据