4.6 Article

Medial Femoral Condyle Cartilage Defect Biomechanics: Effect of Obesity, Defect Size, and Cartilage Thickness

期刊

AMERICAN JOURNAL OF SPORTS MEDICINE
卷 44, 期 2, 页码 409-416

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/0363546515613517

关键词

osteochondral defects; medial femoral condyle; microfracture

资金

  1. DMC Sports Medicine group
  2. Detroit Medical Center Orthopaedic Surgery Residency Program

向作者/读者索取更多资源

Background: Medial femoral condyle (MFC) chondral defects cause knee pain. Clinical studies have shown worse functional outcomes and cartilage defect fill rates after microfracture in obese patients (BMI 30) and for defects with size 2 cm(2). Purpose: To determine the effect of obesity, defect size, and cartilage thickness on the force sustained at the base of full-thickness MFC cartilage defects during weightbearing. Study Design: Controlled laboratory study. Methods: Eight human cadaveric knees were loaded in 15 degrees of flexion. A sensor measured force across the medial compartment. The area at the base of the defect protected from load, termed the area of containment, was quantified, and loads simulating weightbearing for BMIs of 20, 30, and 40 were applied. A full-thickness cartilage defect was created on the MFC. Cycles of loads were applied for defect sizes with diameters of 6, 8, 10, 12, 14, 16, 18, and 20 mm. A second sensor recorded force at the base of the defect for defects with diameters of 14, 16, 18, and 20 mm. Results: Loads simulating BMI 30 led to a decrease in the area of containment for all defects 14 mm in diameter (P .038). Base of defect force increased for defects 16 mm in diameter (area, 2 cm(2)) between loaded and unloaded states (P .042) and for loads simulating BMI 30 (P .045). Cartilage rim thickness <2 mm showed higher base of defect force than did thickness 2 mm, for all BMI groups (P .025). Conclusion: Increased force at the base of MFC cartilage defects was observed for weightbearing loads simulating BMI 30, for defect size 2 cm(2), and for rim thickness <2 mm. This may lead to a biomechanically unfavorable environment after microfracture in these patient subsets. Clinical Relevance: These biomechanical findings corroborate clinical studies that have noted worse outcomes after microfracture in patients with BMI 30 and cartilage defects of size 2 cm(2). Further clinical studies are needed to compare microfracture with other cartilage restoration procedures in these patient subsets.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据