4.7 Article

Evaluation of cortical current density imaging methods using intracranial electrocorticograms and functional MRI

期刊

NEUROIMAGE
卷 35, 期 2, 页码 598-608

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.neuroimage.2006.12.026

关键词

brain imaging; source imaging; cortical current density; high resolution EEG; Inverse Problem; somatosensory evoked potentials; sensory cortex; central sulcus

资金

  1. NIBIB NIH HHS [R01 EB000178, R01EB00178] Funding Source: Medline
  2. PHS HHS [R013001A2] Funding Source: Medline

向作者/读者索取更多资源

Objective: EEG source imaging provides important information regarding the underlying neural activity from noninvasive electro-physiological measurements. The aim of the present study was to evaluate source reconstruction techniques by means of the intracranial electrocorticograms (ECoGs) and functional MRI. Methods: Five source imaging algorithms, including the minimum norm least square (MNLS), LORETA with L-p-norm (p equal to 1, 1.5 and 2), sLORETA, the minimum Lp-norm (p equal to 1 and 1.5; when p=2, the MNLS method is mathematically equivalent to the minimum LP-norm) and L-1-norm (the linear programming) methods, were evaluated in a group of 10 human subjects, in a paradigm with somatosensory stimulation. Cortical current density (CCD) distributions were estimated from the scalp somatosensory evoked potentials (SEP's), at approximately 30 ms following electrical stimulation of median nerve at the wrist. Realistic geometry boundary element head models were constructed from the MRIs of each subject and used in the CCD analysis. Functional MRI results obtained from a motor task and sensory stimulation in all subjects were used to identify the central sulcus, motor and sensory areas. In three patients undergoing neurosurgical evaluation, ECoGs were recorded in response to the somatosensory stimulation, and were used to help determine the central sulcus and the sensory cortex. Results: The CCD distributions estimated by the Lp-norm and LORETA-L-p methods were smoother when the p values were high. The LORETA based on the L-1-norm performed better than the LORETA-L-2 method for imaging well localized sources such as the P30 component of the SEP. The mean and standard deviation of the distance between the location of maximum CCD value and the central sulcus, estimated by the minimum Lp-norm (with p equal to 1), L-1-norm (the Linear programming) and LORETA-Lp (with p equal to 1) methods, were 4, 7, 7 rum and 3, 4, 2 rum, respectively (after converting into Talairach coordinates). The mean and standard deviation of the aforementioned distance, estimated by the MNLS, LORETA with Lp-norm (p equal to 1.5 and 2.0), sLORETA and the minimum Lp-norm (p equal to 1.5) methods, were over 11 mm and 6 mm, respectively. Conclusions: The present experimental study suggests that L-1-normbased algorithms provide better performance than L-2 and L-1.5-normbased algorithms, in the context of CCD imaging of well localized sources induced by somatosensory electrical stimulation of median nerve at the wrist. (c) 2006 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据