4.2 Article

A pilot randomized controlled crossover study comparing regional heparinization to regional citrate anticoagulation for continuous venovenous hemofiltration

期刊

INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS
卷 30, 期 4, 页码 301-307

出版社

SAGE PUBLICATIONS LTD
DOI: 10.1177/039139880703000404

关键词

acute renal failure; anticoagulation; continuous renal replacement therapy; continuous venovenous hemofiltration; citrate; heparin

向作者/读者索取更多资源

Objective: To evaluate the efficacy and safety of a regional heparinization and a regional citrate method of anticoagulation in CWH. Design: Randomized controlled cross-over study Subjects: Ten critically ill patients with acute renal failure Setting: ICU of tertiary hospital Intervention: CWH was performed with pre-filter fluid replacement at 2000ml/h and a blood flow rate of 150ml/min. Regional heparinization was by the administration of heparin pre-filter at 1500IU/h and protamine post-filter at 15mg/h. Regional citrate anticoagulation was by means of a citrate-based replacement fluid (14 mmol/L) administered pre-dilution. Results: We studied nine males and one female. The mean age and APACHE II score were 70.5 and 17 respectively. Median circuit life was 13 hours (IQR 9.28) for the regional heparinization method compared to 17 hours (IQR 12,19.5) for the regional citrate method (p=0.77). There were no episodes of bleeding in either group. Conclusion: Regional heparinization and regional citrate anticoagulation achieve similar circuit life in critically ill patients receiving CWH.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据