Cumulative clamp load loss due to a fully reversed cyclic service load acting on an initially yielded bolted joint system

期刊

JOURNAL OF MECHANICAL DESIGN
卷 129, 期 4, 页码 421-433

出版社

ASME
DOI: 10.1115/1.2429700

关键词

threaded fasteners; clamp load loss; yield tightening; flanged connections

向作者/读者索取更多资源

The amount of clamp load loss due to a fully reversed cyclic service load is determined for a bolted assembly in which the fastener and the Joint were both tightened initially beyond their respective proportional limits. The cyclic reversed load acts ill a direction parallel to the bolt axis. During the first half of each cycle, the cyclic load acts (is tensile separating force that increases the fastener tension further into the nonlinear range; it simultaneously reduces the joint clamping force. Thus, after the first one half of the cycle, the clamp load is reduced from its initial value due to the plastic elongation of the fastener During the second half cycle, the cyclic load compresses the joint further into the plastic range; simultaneously, it reduces the fastener tension. Due to the permanent set in the compressed joint, the clamp load is decreased further at the end of the second half cycle of the service load. The cumulative clamp load loss due to the permanent set in both the fastener and the joint is analytically determined using a nonlinear model. Variables investigated ill this study include the joint-to-fastener stiffness ratio, the ratio of the initial fastener tension to its elastic limit, and the ratio of the external force to its maximum tensile value that would trigger joint separation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据