4.7 Article

Experimental analysis and simulation of the gas transport in dense Hyflon® AD60X membranes:: Influence of residual solvent

期刊

POLYMER
卷 48, 期 9, 页码 2619-2635

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.polymer.2007.02.068

关键词

Hyflon AD60X; gas separation membrane; residual solvent

向作者/读者索取更多资源

The present paper discusses the tendency of solution-cast Hyflon (R) AD membranes to retain unexpectedly high amounts of solvent, the possible reasons of this phenomenon and its effect on the membrane performance. Dense membranes, prepared by solution-casting and subsequent evaporation, showed large differences in their thermal, mechanical and transport properties, depending on the residual solvent content. Complete solvent removal required heating under vacuum up to well above the glass transition temperature. Analysis of the permeability, diffusion and solubility coefficients of six permanent gases showed that plasticization by the residual solvent reduces the permselectivity and increases the permeability. Data of solution-cast membranes after complete solvent removal compare well with those of a melt-pressed sample. Experimental gas transport parameters were confronted with simulated data, obtained by the Gusev-Suter Transition-State Theory (TST) method and by molecular dynamics (MD) simulations. H-1 High Resolution Magic Angle Spinning Nuclear Magnetic Resonance spectroscopic analysis of the residual solvent in the polymer matrix did not reveal a particular interaction between polymer and solvent, suggesting that the solvent retention is mainly diffusion controlled. (c) 2007 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据