4.6 Article

Oxygen Desaturation Index from Nocturnal Oximetry: A Sensitive and Specific Tool to Detect Sleep-Disordered Breathing in Surgical Patients

期刊

ANESTHESIA AND ANALGESIA
卷 114, 期 5, 页码 993-1000

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1213/ANE.0b013e318248f4f5

关键词

-

资金

  1. Physicians Services Incorporated Foundation
  2. University Health Network Foundation
  3. ResMed Foundation
  4. Respironic Foundation
  5. Department of Anesthesia, University Health Network-Mount Sinai Hospital
  6. University of Toronto, Toronto, ON, Canada

向作者/读者索取更多资源

INTRODUCTION: It is impractical to perform polysomnography (PSG) in all surgical patients suspected of having sleep disordered breathing (SDB). We investigated the role of nocturnal oximetry in diagnosing SDB in surgical patients. METHOD: All patients 18 years and older who visited the preoperative clinics for scheduled inpatient surgery were approached for study participation. Patients expected to have abnormal electroencephalographic findings were excluded. All patients underwent an overnight PSG at home with a portable device and a pulse oximeter. The PSG recordings were scored by a certified sleep technologist. The oximetry recordings were processed electronically. RESULT: Four hundred seventy-five patients completed the study: 217 males and 258 females, aged 60 +/- 11 years, and body mass index 31 +/- 7 kg/m(2). The apnea-hypopnea index (AHI), the average number of episodes of apnea and hypopnea per hour of sleep, was 9.1 (2.8 to 21.4) [median (interquartile range)] and 64% patients had AHI > 5. There was a significant correlation between oxygen desaturation index (ODI, hourly average number of desaturation episodes) and cumulative time percentage with Spo(2) < 90% (CT90) from nocturnal oximetry, with the parameters measuring sleep breathing disorders from PSG. Compared to CT90, ODI had a stronger correlation and was a better predictor for AHI. The area under receiver operator characteristics curve for ODI to predict AHI > 5, AHI > 15, and AHI > 30 was 0.908 (CI: 0.880 to 0.936), 0.931 (CI: 0.090 to 0.952), and 0.958 (CI: 0.937 to 0.979), respectively. The cutoff value based on the maximal accuracy for ODI to predict AHI > 5, AHI > 15, and AHI > 30 was ODI > 5, ODI > 15, and ODI >30. The accuracy was 86% (CI: 83%-88%), 86% (CI: 83%-89%), and 94% (CI: 92%-96%), respectively. The ODI > 10 demonstrated a sensitivity of 93% and a specificity of 75% to detect moderate and severe SDB. CONCLUSIONS: ODI from a high-resolution nocturnal oximeter is a sensitive and specific tool to detect undiagnosed SDB in surgical patients. (Anesth Analg 2012;114:993-1000)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据