BACKGROUND: The pulmonary artery catheter (PAC) continues to be used for monitoring of hemodynamics in patients undergoing coronary artery bypass graft (CABG) surgery despite concerns raised in other settings regarding both effectiveness and safety. Given the relative paucity of data regarding its use in CABG patients, and given entrenched practice patterns, we assessed the impact of PAC use on fatal and nonfatal CABG outcomes as practiced at a diverse set of medical centers. METHODS: Using a formal prospective observational study design, 5065 CABG patients from 70 centers were enrolled between November 1996 and June 2000 using a systemic sampling protocol. Propensity score matched-pair analysis was used to adjust for differences in likelihood of PAC insertion. The predefined composite endpoint was the occurrence of any of the following: death (any cause), cardiac dysfunction (myocardial infarction or congestive heart failure), cerebral dysfunction (stroke or encephalopathy), renal dysfunction (dysfunction or failure), or pulmonary dysfunction (acute respiratory distress syndrome). Secondary variables included treatment indices (inotrope use, fluid administration), duration of postoperative intubation, and intensive care unit length of stay. After categorization based on PAC and transesophageal echocardiography use (both, neither, PAC only, transesophageal echocardiography only), we performed the primary analysis contrasting PAC only and neither (total, 3321 patients), from which propensity paring yielded 1273 matched pairs. RESULTS: The primary endpoint occurred in 271 PAC patients versus 196 without PAC (21.3% vs. 15.4%; adjusted odds ratio [AOR], 1.68; 95% confidence interval [CI], 1.24 to 2.26; P < 0.001). The PAC group had an increased risk of all-cause mortality, 3.5% vs 1.7% (AOR, 2.08; 95% CI, 1.11 to 3.88; P = 0.02) and an increased risk of cardiac (AOR, 1.58; 95% CI, 1.14 to 2.20; P = 0.007), cerebral (AOR, 2.02; 95% CI, 1.08 to 3.77; P = 0.03) and renal (AOR, 2.47; 95% CI, 1.68 to 3.62; P < 0.001) morbid outcomes. PAC patients received inotropic drugs more frequently (57.8% vs 50.0%; P < 0.001), had a larger positive IV fluid balance after surgery (3220 mL vs 3022 mL; P = 0.003), and experienced longer time to tracheal extubation (15.40 hours [11.28/20.80] versus 13.18 hours [9.58/19.33], median plus Q1/Q3 interquartile range; P < 0.0001). Use of PAC was also associated with prolonged intensive care unit stay (14.5% vs 10.1%; AOR, 1.55; 95% CI, 1.06 to 2.27; P = 0.02). CONCLUSIONS: Use of a PAC during CABG surgery was associated with increased mortality and a higher risk of severe end-organ complications in this propensity-matched observational study. A randomized controlled trial with defined hemodynamic goals would be ideal to either confirm or refute our findings. (Anesth Analg 2011;113:994-1002)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据