4.7 Article

Speciation of Cr(III) and Cr(VI) after column solid phase extraction on Amberlite XAD-2010

期刊

JOURNAL OF HAZARDOUS MATERIALS
卷 143, 期 1-2, 页码 112-117

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jhazmat.2006.08.074

关键词

speciation; chromium; solid-phase extraction; amberlite XAD-2010; atomic absorption spectrometry

向作者/读者索取更多资源

A speciation procedure for Cr(III) and Cr(VI) based on column solid phase extraction on Amberlite XAD-2010 and flame atomic absorption spectrometry combination. Cr(VI) was quantitatively recovered on Amberlite XAD-2010 resin at pH range of 2.0-3.0 as its diethyldithiocarbamate complex, while the recoveries of Cr(III) was below 5%. The influences of the various parameters including amounts of the reagents, eluent type and its volume, sample volume, etc., on the quantitative recoveries were examined. The interference of matrix and coexistent elements for method were studied. The detection limit (corresponding to three times the standard deviation of the blank) and the enrichment factor for Cr(VI) were found to be 1.28 mu g/L and 25, respectively. To verify the accuracy of the method, drinking water certified reference material (CRM-TMDW-500) was analyzed and the results obtained were in good agreement with the certified value. The proposed method has been successfully applied to the speciation of Cr(III) and Cr(VI) in water samples and preconcentration of total chromium in environmental samples. (C) 2006 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据