4.7 Article Proceedings Paper

Measurement of triclosan in water using a magnetic particle enzyme immunoassay

期刊

JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY
卷 55, 期 10, 页码 3758-3763

出版社

AMER CHEMICAL SOC
DOI: 10.1021/jf0632841

关键词

ELISA; immunoassay; residue; water monitoring; triclosan

向作者/读者索取更多资源

A sensitive magnetic particle-based immunoassay to determine triclosan [5-chloro-2-(2,4-dichlorophenoxy)phenol] in drinking water and wastewater was developed. Rabbit antiserum was produced by immunizing the rabbit with 6-[5-chloro-2-(2,4-dichlorophenoxy)phenoxy]hexanoic acid-keyhole limpet hemocyanin. Horseradish peroxidase was conjugated with 4-[3-bromo-4-(2,4-dibromophenoxy)phenoxy]butyric acid via N-hydroxysuccinimide (NHS) and 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC). The triclosan antibody was coupled to magnetic particles via the NHS/EDC reaction. The antibodies were able to recognize some structurally related polybrominated biphenyl ethers but did not recognize various common pollutants that were less similar to the hapten. The ELISA could detect triclosan in standard solution (25% methanol/H2O v/v) at 20 ppt and its metabolite, methyl-triclosan, at 15 ppt. Water samples from different treatment stages were prepared to contain 25% methanol and analyzed directly without any sample extraction or preconcentration. The results showed that recoveries were > 80% and the % CV was < 10%, demonstrating the assay was both accurate and precise. Application of the triclosan ELISA to water treatment plants showed that tap water at various purification stages had low concentrations of triclosan (< 20 ppt) and required an increased sample size for appropriate detection and measurement. Application of ELISA to the wastewater treatment plants (WWTP) demonstrated high concentrations of triclosan (in general, > 3000 ppt in water entering the WWTP) with the levels decreasing as the water proceeded through the processing plant (< 500 ppt at outflow sewage). The ELISA measurement was shown to be equivalent to the more specific GC-MS analysis on a number of wastewater treatment samples with a high degree of correlation, with the exception of a few samples with very high triclosan concentrations (> 5000 ppt). Measurement of methyl-triclosan (in WWTP) using GC-MS demonstrated the levels of this compound to be low. In summary, a rapid, sensitive, accurate, and precise magnetic particle-based immunoassay has been developed for triclosan analysis, which can serve as a cost-effective monitoring tool for various water samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据