期刊
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
卷 852, 期 1-2, 页码 174-179出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.jchromb.2007.01.012
关键词
fluconazole; high performance liquid chromatography (HPLC); validation; bioequivalence; human plasma
A sensitive and accurate HPLC-UV method for the quantification of fluconazole (FLA) level in human plasma has been developed. The sample was prepared by one-step liquid-liquid extraction (ILLE) of FLA from plasma using dichloromethane. Phenacetin was used as the internal standard. The chromatographic retention times of FLA and phenacetin were 4.6 and 8.3 min, respectively. The lower limit of quantitation (LLOQ) was 0.05 mu g/mL, and no interferences were detected in the chromatograms. The devised HPLC-UV method was validated by evaluating its intra- and inter-day precisions and accuracies in a linear concentration range between 0.05 and 10.00 mu g/mL. The devised method was successfully applied to a bioequivalence studies involving the oral administration of a single 150 mg FLA tablet and 3 x 50 mg FLA capsules in healthy Korean male volunteers. (c) 2007 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐