4.6 Article

Development of a monoclonal antibody-based direct competitive enzyme-linked immunosorbent assay for a new β-adrenergic agonist phenylethanolamine A

期刊

ANALYTICAL METHODS
卷 6, 期 15, 页码 5942-5950

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c4ay00682h

关键词

-

资金

  1. Natural Science Foundation Programs of Zhejiang Province [LY13C200009]
  2. Innovation Team of Zhejiang Province [2010R50028]
  3. Key Science and Technological Achievement Transformation Project of Zhejiang Province [2011E61018]
  4. Important Science and Technology Specific Program of Zhejiang Province, China [2012C12013-3]

向作者/读者索取更多资源

A direct competitive enzyme-linked immunosorbent assay (dcELISA) based on a monoclonal antibody was developed for detecting a new beta-adrenergic agonist phenylethanolamine A (PEAA). A PEAA derivative, PEAA-NH2, was synthesized by hydrogenation using RANEY (R) nickel as a catalyst, before it was coupled to carrier proteins to generate PEAA-BSA, PEAA-OVA and PEAA-HRP via diazotization and sodium periodate methods, repectively. Three Balb/C mice were immunized with PEAA-BSA as the immunogen, and three clones stably producing antibodies against PEAA were acquired. Subsequently, a dcELISA method was established using the monoclonal antibody (clone 2H8) and PEAA-HRP. With the PEAA concentration range of 0.025-2.025 ng mL(-1), the IC50 value was 0.204 ng mL(-1). The monoclonal antibody was highly specific for PEAA and its derivative (PEAA-NH2), with minor cross-reactivity (CR) with ractopamine (CR = 8.3%) and negligible cross-reactivity with 15 other beta-agonists compounds (CR < 0.1%). For sample testing, the LOD (limit of detection) values of blank samples (pork, swine liver, swine urine and feed) were shown to be 0.431, 0.455, 0.225 and 8.693 ng mL(-1), respectively; the corresponding LOQ (limit of quantification) values were 0.578, 0.647, 0,360 and 14.477 ng mL(-1), respectively. The recovery rates ranged from 82% to 120%. The coefficients of variation were below 13.33% and 10.53% for inter-assay and intra-assay, respectively. Furthermore, the dcELISA was validated by a liquid chromatography tandem mass spectrometry (LC-MS/MS) method, and the result showed a high correlation coefficient between the two methods. Overall, the results suggested this dcELISA method with high sensitivity and specificity could be used to detect PEAA residues in real samples reliably.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据