期刊
ANALYTICAL METHODS
卷 4, 期 8, 页码 2375-2380出版社
ROYAL SOC CHEMISTRY
DOI: 10.1039/c2ay05537f
关键词
-
资金
- CNPq
- CAPES
- FAPESP
- INCTAA grant
This paper concerns the use of digital images of seston to monitor different ponds of a domestic wastewater treatment plant. For this purpose, a commercial camera was employed to photograph the seston samples and an automatic procedure based on the Hough Circle Transform was used to segment the resulting picture. Multivariate techniques were then employed to analyze the seston images in terms of their RGB colour components. The results indicate that such colour components undergo a significant change after each stage of the wastewater treatment process, according to a Hotelling T-2 test (p-value smaller than 10(-4)). This finding was corroborated by the use of quadratic discriminant analysis (QDA), which resulted in the correct classification of all samples according to the treatment stage. In addition, it was found that differences in the illumination of the samples can be standardized by converting the RGB data to the YCbCr format and correcting the luminance (Y) component. This correction may unveil changes in the seston features that were previously masked by the illumination variability.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据