4.7 Article Proceedings Paper

Outbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve

期刊

CLINICAL INFECTIOUS DISEASES
卷 44, 期 11, 页码 1408-1414

出版社

OXFORD UNIV PRESS INC
DOI: 10.1086/517538

关键词

-

向作者/读者索取更多资源

Background. Needleless intravascular catheter connector valves have been introduced into clinical practice to minimize the risk of needlestick injury. However, infection-control risks associated with these valves may be underappreciated. In March 2005, a dramatic increase in bloodstream infections was noted in multiple patient care units of a hospital in temporal association with the introduction of a needleless valve into use. Methods. Surveillance for primary bloodstream infection was conducted using standard methods throughout the hospital. Blood culture contamination rates were monitored. Cultures were performed using samples obtained from intravascular catheter connector valves. Results. The relative risk of bloodstream infection for the time period in which the suspect connector valve was in use, compared with baseline, was 2.79 (95% confidence interval, 2.27-3.43). In critical care units, the rate of primary bloodstream infection increased with the introduction of the valve from 3.87 infections per 1000 catheter-days to 10.64 infections per 1000 catheter-days (P <.001), and it decreased to 5.59 infections per 1000 catheter-days (P=.02) in the 6 months following removal of the device from use. Similarly, in inpatient nursing units, the rate of bloodstream infection increased from 3.47 infections per 1000 catheter-days to 7.3 infections per 1000 catheter-days (P=.57) following introduction of the device, and it decreased to 2.88 infections per 1000 catheter-days (P=.57) following removal of the device from use. Similar events occurred in the cooperative care Pp. 57 units. The rate of blood culture contamination did not substantially change over the course of the study. Of 37 valves that were subjected to microbiological sample testing, 24.3% yielded microbes, predominantly coagulase-negative staphylococci. Conclusion. A significant association between primary bloodstream infection and a needleless connector valve was observed. Evaluation of needleless connector valves should include a thorough assessment of infection risks in prospective randomized trials prior to their introduction to the market.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据