4.6 Article

Electric fields and corona currents in needle-to-meshed plate gaps

期刊

JOURNAL OF PHYSICS D-APPLIED PHYSICS
卷 40, 期 11, 页码 3363-3370

出版社

IOP PUBLISHING LTD
DOI: 10.1088/0022-3727/40/11/017

关键词

-

向作者/读者索取更多资源

This paper is aimed at evaluating the electric field, the corona onset voltage and the corona current in negatively stressed needle-to-meshed plate gaps as compared with the case of using a flat plate. The charge simulation method is used for calculating the electric field in the gap. The onset voltage is evaluated based on the calculated field and the criterion for self-recurring single electron-avalanches in the ionization-zone around the needle tip. The corona current - voltage characteristics were measured for thin and thick needles at two gap spacings with meshed and flat plates. The corona currents with meshed plates are lower than those with a flat plate; even the corona onset voltage with the flat plate is higher than that with the meshed plate.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据