4.8 Article

Multilayer Paper-Based Device for Colorimetric and Electrochemical Quantification of Metals

期刊

ANALYTICAL CHEMISTRY
卷 86, 期 7, 页码 3555-3562

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac5000224

关键词

-

资金

  1. National Institute for Occupational Safety and Health [R21OH010050]
  2. Chulalongkorn University
  3. Thailand Research Fund, through the Royal Golden Jubilee Ph.D. Program [PHD/0251/2552]
  4. Ratchadaphiseksomphot Endowment Fund
  5. National Research Council of Thailand
  6. Thailand Research Fund [BRG5380008]
  7. Chulalongkorn University Centenary Academic Development Project
  8. National Research University Project of CHE
  9. Ratchadaphisaksomphot Endowment Fund

向作者/读者索取更多资源

The release of metals and metal-containing compounds into the environment is a growing concern in developed and developing countries, as human exposure to metals is associated with adverse health effects in virtually every organ system. Unfortunately, quantifying metals in the environment is expensive; analysis costs using certified laboratories typically exceed $100/sample, making the routine analysis of toxic metals cost-prohibitive for applications such as occupational exposure or environmental protection. Here, we report on a simple, inexpensive technology with the potential to render toxic metals detection accessible for both the developing and developed world that combines colorimetric and electrochemical microfluidic paper-based analytical devices (mPAD) in a three-dimensional configuration. Unlike previous mPADs designed for measuring metals, the device reported here separates colorimetric detection on one layer from electrochemical detection on a different layer. Separate detection layers allows different chemistries to be applied to a single sample on the same device. To demonstrate the effectiveness of this approach, colorimetric detection is shown for Ni, Fe, Cu, and Cr and electrochemical detection for Pb and Cd. Detection limits as low as 0.12 mu g (Cr) were achieved on the colorimetric layer while detection limits as low as 0.25 ng (Cd and Pb) were achieved on the electrochemical layer. Selectivity for the target analytes was demonstrated for common interferences. As an example of the device utility, particulate metals collected on air sampling filters were analyzed. Levels measured with the mPAD matched known values for the certified reference samples of collected particulate matter.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据