4.8 Article

Fluorous Membrane Ion-Selective Electrodes for Perfluorinated Surfactants: Trace-Level Detection and in Situ Monitoring of Adsorption

期刊

ANALYTICAL CHEMISTRY
卷 85, 期 15, 页码 7471-7477

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac401424j

关键词

-

资金

  1. National Science Foundation [OISE CHE-0809328, SBIR 113251]
  2. MRSEC program of the NSF [DMR-0212302, DMR-0819885]
  3. Welch Foundation [A-1656]
  4. NSF/Lando summer undergraduate research fellowship program of the University of Minnesota [CHE-0552622]
  5. Directorate For Engineering
  6. Div Of Industrial Innovation & Partnersh [1256626] Funding Source: National Science Foundation
  7. Division Of Chemistry
  8. Direct For Mathematical & Physical Scien [0809328] Funding Source: National Science Foundation

向作者/读者索取更多资源

Ion-selective electrodes (ISEs) with fluorous anion-exchanger membranes for the potentiometric detection of perfluorooctanoate (PFO-) and perfluorooctanesulfonate (PFOS-) were developed. Use of an anion-exchanger membrane doped with the tetraallcylphosphonium derivative R-f8 CH2)(2)) (R-f6(CH2)(2))(3)P+ and an optimized measurement protocol resulted in detection limits of 2.3 X 10(-9) M (1.0 ppb) for PFO- and 8.6 x 10(-10) M (0.43 ppb) for PFOS-. With their higher selectivity for PFO- over OH-, membranes containing the alternative anion exchanger (R-f6(CH2)(3))(3)PN+P((CH2)(3-)R-f6)(3) with a bis(phosphoranylidene)ammonium group further improved the detection limit for PFO- to 1.7 X 10(-10) M (0.070 ppb). These values are comparable with results obtained using well-established techniques such as gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), and liquid chromatography-tandem mass spectrometry (LC-MS-MS), but the measurement with ISEs avoids lengthy sample preconcentration, can be performed in situ, and is less costly. Even when eventual spectrometric confirmation of analyte identity is required, prescreening of large numbers of samples or in situ monitoring with ISEs may be of substantial benefit. To demonstrate a real-life application of these electrodes, in situ measurements were performed of the adsorption of PFOS- onto Ottawa sand, which is a standard sample often used in environmental sciences. The results obtained are consistent with those from an earlier LC-MS study, validating the usefulness of these sensors for environmental studies. Moreover, PFOS- was successfully measured in a background of water from Carnegie Lake.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据