4.8 Article

Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents

期刊

ANALYTICAL CHEMISTRY
卷 84, 期 3, 页码 1380-1385

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac202391w

关键词

-

资金

  1. Office of the Director, National Institutes of Health (OD)
  2. National Institute of Neurological Disorders and Stroke (NINDS) [U01 NS058161-01]
  3. National Natural Science Foundation of China [21075047]
  4. Department of Energy's Office of Biological and Environmental Research at Pacific Northwest National Laboratory
  5. DOE [DE-AC05-76RL01830]

向作者/读者索取更多资源

An integrated lateral flow test strip with an electrochemical sensor (LFTSES) device with rapid, selective, and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of postexposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of the total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows a linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with a detection limit of 0.02 nM. On the basis of this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective, and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据