4.8 Article

High-Throughput Method Development for Sensitive, Accurate, and Reproducible Quantification of Therapeutic Monoclonal Antibodies in Tissues Using Orthogonal Array Optimization and Nano Liquid Chromatography/Selected Reaction Monitoring Mass Spectrometry

期刊

ANALYTICAL CHEMISTRY
卷 84, 期 10, 页码 4373-4382

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac2034166

关键词

-

资金

  1. Industrial Consortium Grant
  2. Center of Protein Therapeutics, SUNY-Buffalo
  3. NIH [CA118213, DA027528]
  4. AHA [12SDG9450036]

向作者/读者索取更多资源

Although liquid chromatography/mass spectrometry using selected reaction monitoring (LC/SRM-MS) holds great promise for targeted protein analysis, quantification of therapeutic monoclonal antibody (mAb) in tissues represents a daunting challenge due to the extremely low tissue levels, complexity of tissue matrixes, and the absence of an efficient strategy to develop an optimal LC/SRM-MS method. Here we describe a high-throughput, streamlined strategy for the development of sensitive, selective, and reliable quantitative methods of mAb in tissue matrixes. A sensitive nano-LC/nanospray-MS method was employed to achieve a low lower limit of quantification (LOQ). For selection of signature peptides (SP), the SP candidates were identified by a high-resolution Orbitrap and then optimal SRM conditions for each candidate were obtained using a high-throughput, on-the-fly orthogonal array optimization (OAO) strategy, which is capable of optimizing a large set of SP candidates within a single nano-LC/SRM-MS run. Using the optimized conditions, the candidates were experimentally evaluated for both sensitivity and stability in the target matrixes, and SP selection was based on the results of the evaluation. Two unique SP, respectively from the light and heavy chain, were chosen for quantification of each mAb. The use of two SP improves the quantitative reliability by gauging possible degradation/modification of the mAb. Standard mAb proteins with verified purities were utilized for calibration curves, to prevent the quantitative biases that may otherwise occur when synthesized peptides were used as calibrators. We showed a proof of concept by rapidly developing sensitive nano-LC/SRM-MS methods for quantifying two mAb (8c2 and cT84.66) in multiple preclinical tissues. High sensitivity was achieved for both mAb with LOQ ranged from 0.156 to 0.312 mu g/g across different tissues, and the overall procedure showed a wide dynamic range (>= 500-fold) and good accuracy [relative error (RE) < 18.8%] and precision [interbatch relative standard deviation (RSD) < 18.1%, intrabatch RSD < 17.2%]. The quantitative method was applied to a comprehensive investigation of the steady-state tissue distribution of 8c2 in wild-type mice versus those deficient in FcRn alpha-chain, Fc gamma IIb, and Fc gamma RI/Fc gamma RIII, following a chronic dosing regimen. This work represents the first extensive quantification of mAb in tissues by an LC/MS-based method.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据