4.8 Article

Precise Determination of the Absolute Isotopic Abundance Ratio and the Atomic Weight of Chlorine in Three International Reference Materials by the Positive Thermal Ionization Mass Spectrometer-Cs2Cl+-Graphite Method

期刊

ANALYTICAL CHEMISTRY
卷 84, 期 23, 页码 10350-10358

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac302498q

关键词

-

资金

  1. National 973 project [2012CB416706]
  2. National Natural Science Foundation of China [41073002, 40973002]
  3. Fundamental Research Funds for the Central Universities [020614330005, 2009-II-8]
  4. State Key Laboratory for Mineral Deposits Research (Nanjing University)

向作者/读者索取更多资源

Because the variation in chlorine isotopic abundances of naturally occurring chlorine bearing substances is significant, the IUPAC Inorganic Chemistry Division, Commission on Isotopic Abundances and Atomic Weights (CIAAW-IUPAC) decided that the uncertainty of atomic weight of chlorine (A(r)(CI)) should be increased so that the implied range was related to terrestrial variability in 1999 (Coplen, T. B. Atomic weights of the elements 1999 (IUPAC Technical Report), Pure Appl. Chem. 2001, 73(4), 667-683; and then, it emphasized that the standard atomic weights of ten elements including chlorine were not constants of nature but depend upon the physical, chemical, and nuclear history of the materials in 2009 (Wieser, M. E.; Coplen, T. B. Pure Appl. Chem. 2011, 83(2), 359-396). According to the agreement by CIAAW that an atomic weight could be defined for one specified sample of terrestrial origin (Wieser, M. E.; Coplen, T. B. Pure Appl. Chem, 2011, 83(2), 359-396), the absolute isotope ratios and atomic weight of chlorine in standard reference materials (NIST 975, NIST 975a, ISL 354) were accurately determined using the high-precision positive thermal ionization mass spectrometer (PTIMS)-Cs2Cl+-graphite method. After eliminating the weighing error caused from evaporation by designing a special weighing container and accurately determining the chlorine contents in two highly enriched (NaCl)-Cl-37 and (NaCl)-Cl-35 salts by the current constant coulometric titration, one series of gravimetric synthetic mixtures prepared from two highly enriched (NaCl)-Cl-37 and (NaCl)-Cl-35 salts was used to calibrate two thermal ionization mass spectrometers in two individual laboratories. The correction factors (i.e., K-37/35 = R-37/35meas/R-37/35calc were obtained from five cycles of iterative calculations on the basis of calculated and determined R(Cl-37/Cl-35) values in gravimetric synthetic mixtures. The absolute R(Cl-37/Cl-35) ratios for NIST SRM 975, NIST 975a, and ISL 354 by the precise calibrated isotopic composition measurements are 0.319876 +/- 0.000067, 0.319768 +/- 0.000187, and 0.319549 +/- 0.000044, respectively. As a result, the atomic weights of chlorine in NIST 975, NIST 975a, and ISL 354 are derived as 35,45284(8), 35.45272(21), and 35.45252(2) individually, which are consistent with the issued values of 35.453(2) by IUPAC in 1999.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据