4.8 Article

Exploiting Metal-Organic Coordination Polymers as Highly Efficient Immobilization Matrixes of Enzymes for Sensitive Electrochemical Biosensing

期刊

ANALYTICAL CHEMISTRY
卷 83, 期 17, 页码 6511-6517

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac200471v

关键词

-

资金

  1. National Natural Science Foundation of China [90713018, 21075036]
  2. State Special Scientific Project on Water Treatment [2009ZX07212-001-06]
  3. Foundations of Hunan Provincial Education Department and Hunan Province [11JJ4014]
  4. Program for Science and Technology Innovative Research Team in Higher Educational Institutions of Hunan Province
  5. State Key Laboratories of Chemo/Biosensing and Chemometrics [200902]

向作者/读者索取更多资源

We report on the exploitation of metal organic coordination polymers (MOCPs) as new and efficient matrixes to immobilize enzymes for amperometric biosensing of glucose or phenols. A ligand, 2,5-dimercapto-1,3,4-thiadiazole (DMcT), two metallic salts, NaAuCl(4) and Na(2)PtCl(6), and two enzymes, glucose oxidase (GOx) and tyrosinase, are used to demonstrate the novel concept. Briefly, one of the metallic salts is added into an aqueous suspension containing DMcT and one of the enzymes to trigger the metal organic coordination reaction, and the yielded MOCPs-enzyme biocomposite (MEBC) is then cast-coated on an Au electrode for biosensing. The aqueous-phase coordination polymerization reactions of the metallic ions with DMcT are studied by visual inspection as well as some spectroscopic, microscopic, and electrochemical methods. The thus-prepared glucose and phenolic biosensors perform better in analytical performance (such as sensitivity and limit of detection) than those prepared by the conventional chemical and/or electrochemical polymerization methods and most of the reported analogous biosensors, as a result of the improved enzyme load/activity and mass-transfer efficiency after using the MOCPs materials with high adsorption/encapsulation capability and unique porous structure. For instance, the detection limit for catechol is as low as 0.2 nM here, being order(s) lower than those of most of the reported analogues. The enzyme electrode was also used to determine catachol in real samples with satisfactory results. The emerging MOCPs materials and the suggested aqueous-phase preparation strategy may find wide applications in the fields of bioanalysis, biocatalysis, and environmental monitoring.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据