4.8 Article

Positive Potential Operation of a Cathodic Electrogenerated Chemiluminescence Immunosensor Based on Luminol and Graphene for Cancer Biomarker Detection

期刊

ANALYTICAL CHEMISTRY
卷 83, 期 10, 页码 3817-3823

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac200237j

关键词

-

资金

  1. National Natural Science Foundation of China [20975060, 21005046]
  2. National Basic Research Program of China [2007CB310500, 2011CB935700]
  3. European Commission [260600]
  4. Tsinghua University

向作者/读者索取更多资源

In this work, we report a cathodic electrogenerated chemiluminescence (ECL) of luminol at a positive potential (ca. 0.05 V vs Ag/AgCl) with a strong light emission on the graphene-modified glass carbon electrode. The resulted graphene-modified electrode offers an excellent platform for high-performance biosensing applications. On the basis of the cathodic ECL signal of luminol on the graphene-modified electrode, an ECL sandwich immunosensor for sensitive detection of cancer biomarkers at low potential was developed with a multiple signal amplification strategy from functionalized graphene and gold nanorods multilabeled with glucose oxidase (GOx) and secondary antibody (Ab(2)). The functionalized graphene improved the electron transfer on the electrode interface and was employed to attach the primary antibody (Ab(1)) due to it large surface area. The gold nanorods were not only used as carriers of secondary antibody (Ab(2)) and GOx but also catalyzed the ECL reaction of luminol, which further amplified the ECL signal of luminol in the presence of glucose and oxygen. The as-proposed low-potential ECL immunosensor exhibited high sensitivity and specificity on the detection of prostate protein antigen (PSA), a biomarker of prostate cancer that was used as a model. A linear relationship between ECL signals and the concentrations of PSA was obtained in the range from 10 pg mL(-1) to 8 ng mL(-1). The detection limit of PSA was 8 pg mL-1 (signal-to-noise ratio of 3). Moreover, the as proposed low-potential ECL immunosensor exhibited excellent stability and reproducibility. The graphene-based ECL immunosensor accurately detected PSA concentration in 10 human serum samples from patients demonstrated by excellent correlations with standard chemiluminescence immunoassay. The results suggest that the as-proposed graphene ECL immunosensor will be promising in the point-of-care diagnostics application of clinical screening of cancer biomarkers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据