4.8 Article

Multiplexed Electrochemical Immunoassay of Phosphorylated Proteins Based on Enzyme-Functionalized Gold Nanorod Labels and Electric Field-Driven Acceleration

期刊

ANALYTICAL CHEMISTRY
卷 83, 期 17, 页码 6580-6585

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac2009977

关键词

-

资金

  1. National Institute of Environmental Health Sciences [U54 ES16015]
  2. National Institute of Health (NIH)
  3. NIH through the National Institute of Neurological Disorders and Stroke [U01 NS058161-01]
  4. National Natural Science Foundation of China [21075047]
  5. Program for Chenguang Young Scientist for Wuhan [200950431184]
  6. Special Fund for Basic Scientific Research of Central Colleges [CCNU10A02005]
  7. U.S. Department of Energy (DOE) [DE-AC05-76RL01830]

向作者/读者索取更多资源

A multiplexed electrochemical immunoassay integrating enzyme amplification and electric field-driven strategy was developed for fast and sensitive quantification of phosphorylated p53 at Ser392 (phospho-p53(392)), Ser15 (phospho-p53(15)), Ser46 (phospho-p53(46)), and total p53 simultaneously. The disposable sensor array has four spatially separated working electrodes, and each of them is modified with different capture antibody, which enables simultaneous immunoassay to be conducted without cross-talk between adjacent electrodes. The enhanced sensitivity was achieved by a multienzyme amplification strategy using gold nanorods (AuNRs) as nanocarrier for coimmobilization of horseradish peroxidase (HRP) and detection antibody (Ab(2)) at a high ratio of HRP/Ab(2), which produced an amplified electrocatalytic response by the reduction of HRP oxidized thionine in the presence of hydrogen peroxide. The immunoreaction processes were accelerated by applying +0.4 V for 3 min and then -0.2 V for 1.5 min; thus, the whole sandwich immunoreactions could be completed in less than 5 min. Under optimal conditions, this method could simultaneously detect phospho-p53(392), phospho-p53(15), phospho-p53(46), and total p53 ranging from 0.01 to 20 nM, 0.05 to 20 nM, 0.1 to 50 nM, and 0.05 to 20 nM with detection limits of 5 pM, 20 pM, 30 pM, and 10 pM, respectively. Accurate determinations of these proteins in human plasma samples were demonstrated by comparison to the standard ELISA method. The disposable immunosensor array shows excellent promise for clinical screening of phosphorylated proteins and convenient point-of-care diagnostics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据