4.8 Article

Magneto-Controlled Graphene Immunosensing Platform for Simultaneous Multiplexed Electrochemical Immunoassay Using Distinguishable Signal Tags

期刊

ANALYTICAL CHEMISTRY
卷 83, 期 13, 页码 5407-5414

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac200969w

关键词

-

资金

  1. National Natural Science Foundation of China [21075019, 20735002]
  2. Research Fund for the Doctoral Program of Higher Education of China [20103514120003]
  3. Award Program for Minjiang Scholar Professorship [XRC-0929]
  4. Alexander von Humboldt-Foundation of Germany
  5. 973 National Basic Research Program of China [2010CB732403]

向作者/读者索取更多资源

A novel flow-through multiplexed immunoassay protocol for simultaneous electrochemical determination of carcinoembryonic (CEA) and alpha-fetoprotein (AFP) in biological fluids was designed using biofunctionalized magnetic graphene nanosheets (MGO) as immunosensing probes and multifunctional nanogold hollow microspheres (GHS) as distinguishable signal tags. The probes were fabricated by means of co-immobilization of primary anti-CEA (Ab(1)) and anti-AFP (Ab(2)) antibodies on the Fe3O4 nanoparticle-coated graphene nanosheets (MGO-Ab(1,2)). The reverse-micelle method was used for the synthesis of distinguishable signal tags by encapsulation of horseradish peroxide (HRP)-thionine and HRP-ferrocene into nanogold hollow microspheres, respectively, which were utilized as labels of the corresponding GHS-Ab(1) and GHS-Ab(2). A sandwich-type immunoassay format was employed for the online detection of CEA and AFP by coupling a flow-through detection cell with an external magnet. The assay was based on the catalytic reduction of H2O2 at the various peak potentials in the presence of the corresponding mediators. Experimental results revealed that the multiplexed electrochemical immunoassay enabled the simultaneous monitoring of AFP and CEA in a single run with wide working ranges of 0.01-200 ng mL(-1) for AFP and 0.01-80 ng mL(-1) for CEA. The detection limits (LODs) for both analytes at 1.0 pg mL(-1) (at 3s(B)) were very low. No obvious nonspecific adsorption and cross-talk were observed during a series. of analyses to detect target analytes. Intraassay and interassay coefficients of variation were < 10%. Importantly, the methodology was evaluated for the analysis of clinical serum specimens, receiving a good correlation between the flow-through multiplexed electrochemical immunoassay and an electrochemiluminescence method as a reference.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据