期刊
ANALYTICAL CHEMISTRY
卷 82, 期 23, 页码 9917-9924出版社
AMER CHEMICAL SOC
DOI: 10.1021/ac102504t
关键词
-
资金
- Department of Defense Unexploded Ordnance Center of Excellence (DoD UXOCOE)
A fluorescent polymer sensor array (FPSA) was made from commercially available fluorescent polymers coated onto glass beads and was tested to assess the ability of the array to discriminate between different analytes in aqueous solution The array was challenged with exposures to 17 different analytes, including the explosives trinitrotoluene (TNT), tetryl, and RDX, various explosive related compounds (ERCs), and nonexplosive electron withdrawing compounds (EWCs) The array exhibited a natural selectivity toward EWCs, while the non-electron withdrawing explosive 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) produced no response Response signatures were visualized by principal component analysis (PCA), and classified by linear discriminant analysis (LDA) RDX produced the same response signature as the sampled blanks and was classified accordingly The array exhibited excellent discrimination toward all other compounds, with the exception of the isomers of nitrotoluene and amino dinitrotoluene Of particular note was the ability of the array to discriminate between the three isomers of dinitrobenzene The natural selectivity of the FPSA toward EWCs, plus the ability of the FPSA to discriminate between different EWCs, could be used to design a sensor with a low false alarm rate and an excellent ability to discriminate between explosives and explosive related compounds
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐