4.8 Article

Identifying, Evaluating, and Controlling Bioanalytical Risks Resulting from Nonuniform Matrix Ion Suppression/Enhancement and Nonlinear Liquid Chromatography-Mass Spectrometry Assay Response

期刊

ANALYTICAL CHEMISTRY
卷 82, 期 23, 页码 9671-9677

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac1013018

关键词

-

向作者/读者索取更多资源

Matrix ion suppression/enhancement is a well observed and discussed phenomenon in electrospray ionization mass spectrometry Nonuniform matrix ion suppression/ enhancement across different types of samples in an analytical run is widely believed to be well compensated for by using a stable isotope labeled internal standard (SIL-IS) in bioanalysis using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) Therefore, the risk of nonuniform matrix ion suppression/ enhancement is usually deemed low when an SIL-IS is used Here, we have identified, evaluated, and proposed solutions to control bioanalytical risks from nonuniform matrix ion suppression/enhancement even with an SIL-IS through a case study using omeprazole Two lots of human blank urine were tested, and ion enhancement of about 500% for omeprazole was observed in one lot but not in the other When a quadratic regression model had to be used, the assay failed the industry acceptance criteria due to unacceptable positive bias for the middle and high quality control (QC) samples The failure was attributed to different extents of matrix ion enhancement between the standards (SIDs) and QCs, which resulted in the misaligned results from the regression model It was concluded that, for the same amount of drug, non uniform ion enhancement for different types of samples (STD or QC) resulted in different ion intensities, therefore leading to different response behaviors (linear or nonlinear) at the mass spectrometer detector A simplified mathematical model was used to evaluate the risk when unmatched response models occurred for different types of samples A diagnostic factor Q (Q = X-uLoQ (-A/B)) was proposed to monitor the risks, where X-uLOQ is the upper limit of quantitation of the assay, A is the quadratic slope of the curve, and B is the linear slope of the curve The potential maximum errors were estimated on the basis of the mathematical model for different scenarios, and Q values were given to control the risks under these conditions for bioanalysis using LC - MS/MS

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据