4.7 Article

Use of handheld X-ray fluorescence spectrometry units for identification of arsenic in treated wood

期刊

ENVIRONMENTAL POLLUTION
卷 148, 期 2, 页码 627-633

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.envpol.2006.11.013

关键词

XRF; treated wood; arsenic; handheld

资金

  1. NIEHS NIH HHS [P50 ES012736, P50 ES012736-04] Funding Source: Medline

向作者/读者索取更多资源

The objective of this study was to evaluate the performance of handheld XRF analyzers on wood that has been treated with a preservative containing arsenic. Experiments were designed to evaluate precision, detection limit, effective depth of analysis, and accuracy of the XRF arsenic readings. Results showed that the precision of the XRF improved with increased sample concentration and longer analysis times. Reported detection limits decreased with longer analysis times to values of less than I mg/kg or 18 mg/kg, depending on the model used. The effective depth of analysis was within the top 1.2 cm and 2.0 cm of sample for wood containing natural gradients of chemical preservative and concentration extremes, respectively. XRF results were found to be 1.5-2.3 times higher than measurements from traditional laboratory analysis. Equations can be developed to convert XRF values to results which are consistent with traditional laboratory testing. (c) 2006 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据