4.4 Article

Comparing effects in spike-triggered averages of rectified EMG across different behaviors

期刊

JOURNAL OF NEUROSCIENCE METHODS
卷 163, 期 2, 页码 283-294

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jneumeth.2007.03.010

关键词

cortex; EMG; motoneuron; motor; muscle

资金

  1. NINDS NIH HHS [R01 NS027686-10A1, R37-NS27686, R01 NS027686-12, R01 NS027686, R37 NS027686, R01 NS027686-11S1, R01 NS027686-13, R01 NS027686-11] Funding Source: Medline

向作者/读者索取更多资源

Effects in spike-triggered averages (SpikeTAs) of rectified electromyographic activity (EMG) compiled for the same neuron-muscle pair during various behaviors often appear different. Do these differences represent significant changes in the effect of the neuron on the muscle activity? Quantitative comparison of such differences has been limited by two methodological problems, which we address here. First, although the linear baseline trend of many SpikeTAs can be adjusted with ramp subtraction, the curvilinear baseline trend of other SpikeTAs can not. To address this problem, we estimated baseline trends using a form of moving average. Artificial triggers were created in 1 ms increments from 40 ms before to 40 ms after each spike used to compile the SpikeTA. These 81 triggers were used to compile another average of rectified EMG, which we call a single-spike increment-shifted average (single-spike ISA). Single-spike ISAs were averaged to produce an overall ISA, which captured slow trends in the baseline EMG while distributing any spike-locked features evenly throughout the 80 ms analysis window. The overall ISA then was Subtracted from the initial SpikeTA, removing an), slow baseline trends for more accurate measurement of SpikeTA effects. Second, the measured amplitude and temporal characteristics of SpikeTA effects produced by the same neuron-muscle pair may vary during different behaviors. But whether or not such variation is significant has been difficult to ascertain. We therefore applied a multiple fragment approach to permit statistical comparison of the measured features of SpikeTA effects for the same neuron-muscle pair during different behavioral epochs. Spike trains recorded in each task were divided into non-overlapping fragments of 100 spikes each, and a separate, ISA-corrected, SpikeTA was compiled for each fragment. Measurements made on these fragment SpikeTAs then were used as test statistics for comparison of peak percent increase, mean percent increase, peak width at half maximum, onset latency, and offset latency. The average of each test statistic measured from the fragment SpikeTAs was well correlated with the single measurement made on the overall SpikeTA. The multiple fragment approach provides a sensitive means of identifying significant changes in SpikeTA effects. (c) 2007 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据