4.5 Article

Simultaneous assessment of average fragment size and amount in minute samples of degraded DNA

期刊

ANALYTICAL BIOCHEMISTRY
卷 388, 期 2, 页码 345-347

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.ab.2009.02.003

关键词

DNA degradation; Minute amounts; DNA size determination; DNA quantification; GMO

资金

  1. La Region Aquitaine, le Pole Aquitaine Sante
  2. Oseo ANVAR

向作者/读者索取更多资源

There is currently no method allowing routine characterization of minute amounts of degraded DNA samples Such is those encountered in forensic science, archived tissues, ancient DNA, extracellular or stool DNA, and processed food. Here we describe and directly validate such a method based, on the one hand, oil a generalized DNA random fragmentation model and, on the other, oil two quantitative polymerase chain reaction (PCR) experiments using two different target sizes. The model also makes it possible to determine the minimum sample amount, the minimum mass average fragment size, and the maximum degradation time necessary to obtain a positive PCR. (c) 2009 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论