4.5 Article

Protein quantification in the presence of poly(ethylene glycol) and dextran using the Bradford method

期刊

ANALYTICAL BIOCHEMISTRY
卷 395, 期 1, 页码 108-110

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.ab.2009.07.045

关键词

-

资金

  1. FCT [SFRH/BD/16296/2004/XS49]
  2. Portuguese Foundation for Science and Technology

向作者/读者索取更多资源

Some experimental methodologies require the quantification of protein in the presence of polymers like poly(ethylene glycol) (PEG) and dextran (DEX). In the aqueous two-phase system (ATPS) extraction of biomolecules, the interference of these phase-forming polymers on the Bradford quantification assay is commonly recognized. However, how these polymers interfere has not been reported hitherto. In this study we show that while dextran concentrations of 20% (w/w) can be used without error, loss of accuracy occurs for solutions with PEG concentrations > 10% (w/w). Above this value a substantial decrease on the assay sensitivity is observed. (C) 2009 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据