4.2 Article

The effect of accelerated ageing of building wires

期刊

FIRE AND MATERIALS
卷 31, 期 5, 页码 311-326

出版社

JOHN WILEY & SONS LTD
DOI: 10.1002/fam.944

关键词

ageing; electric cables; Casico; PVC; cone calorimeter; fire

向作者/读者索取更多资源

The fire performance of two electric cables (building wires) designed for indoor use has been tested, both as new products and after accelerated thermooxidative ageing. The cables were aged for a maximum time of 16.5 weeks at 80 degrees C. The cables are commercially available, and were constructed using a PVC material in one case and a non-halogenated polyolefin-based material, called Casico, in the other. The effects of ageing on the fire performance of the cables, and the chemical changes that have caused the observed fire behaviour, have been investigated and are discussed. Special attention is paid to the behaviour of the plasticizers that are used in the PVC cable, and how the fire behaviour is affected by the loss of plasticizers from the cable and by the migration of plasticizers between the parts of the cable (insulation, bedding and sheathing). Copyright (C) 2007 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据