4.7 Article

An implantable biochip to influence patient outcomes following trauma-induced hemorrhage

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 399, 期 1, 页码 403-419

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-010-4271-x

关键词

Biosensors; Biochips; Biointerfaces; Electroconductive hydrogels; Trauma; Hemorrhage

资金

  1. US Department of Defense (DoDPRMRP) [PR023081/DAMD17-03-1-0172]
  2. Consortium of the Clemson University Center for Bioelectronics, Biosensors and Biochips (C3B)
  3. ABTECH Scientific, Inc.

向作者/读者索取更多资源

Following hemorrhage-causing injury, lactate levels rise and correlate with the severity of injury and are a surrogate of oxygen debt. Posttraumatic injury also includes hyperglycemia, with continuously elevated glucose levels leading to extensive tissue damage, septicemia, and multiple organ dysfunction syndrome. A temporary, implantable, integrated glucose and lactate biosensor and communications biochip for physiological status monitoring during hemorrhage and for intensive care unit stays has been developed. The dual responsive, amperometric biotransducer uses the microdisc electrode array format upon which were separately immobilized glucose oxidase and lactate oxidase within biorecognition layers, 1.0-5.0 mu m thick, of 3 mol% tetraethyleneglycol diacrylate cross-linked p(HEMA-co-PEGMA-co-HMMA-co-SPA)-p(Py-co-PyBA) electroconductive hydrogels. The device was then coated with a bioactive hydrogel layer containing phosphoryl choline and polyethylene glycol pendant moieties [p(HEMA-co-PEGMA-co-HMMA-co-MPC)] for indwelling biocompatibility. In vitro cell proliferation and viability studies confirmed both polymers to be non-cytotoxic; however, PPy-based electroconductive hydrogels showed greater RMS 13 and PC12 proliferation compared to controls. The glucose and lactate biotransducers exhibited linear dynamic ranges of 0.10-13.0 mM glucose and 1.0-7.0 mM and response times (t (95)) of 50 and 35-40 s, respectively. Operational stability gave 80% of the initial biosensor response after 5 days of continuous operation at 37 A degrees C. Preliminary in vivo studies in a Sprague-Dawley hemorrhage model showed tissue lactate levels to rise more rapidly than systematic lactate. The potential for an implantable biochip that supports telemetric reporting of intramuscular lactate and glucose levels allows the refinement of resuscitation approaches for civilian and combat trauma victims.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据