4.4 Article

Using radar direct wave for concrete condition assessment: Correlation with electrical resistivity

期刊

JOURNAL OF APPLIED GEOPHYSICS
卷 62, 期 4, 页码 361-374

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jappgeo.2007.02.003

关键词

concrete; radar; direct wave; condition assessment; corrosion risk; electrical resistivity

向作者/读者索取更多资源

This paper demonstrates that the direct wave of a radar ground-coupled antenna may be used for the nondestructive assessment of the physical condition of concrete, which directly influences the corrosion of the reinforcing bars in the structure. The validity of this method was evaluated by a comparison with the electrical resistivity method, which is frequently used for the evaluation of corrosion probability. Both methods were implemented in the laboratory on 72 concrete samples (25 x 25 x 8 cm 3) with various degrees of saturation and chloride contamination levels. On-site investigations were also carried out on the concrete slab (1080 m(2)) of a car-park. The results of the laboratory tests show that the radar direct signal is strongly affected by variations in concrete moisture and chloride contamination level. The tests performed in real conditions confirm the good correlation between radar direct wave attenuation and electrical resistivity and, thus, the aptitude of the radar direct wave to detect concrete conditions leading to reinforcement corrosion. (c) 2007 Elsevier B.V. All rights reserved.