4.7 Article Proceedings Paper

Characterization of two major urinary metabolites of the PPAR delta-agonist GW1516 and implementation of the drug in routine doping controls

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 396, 期 7, 页码 2479-2491

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-009-3283-x

关键词

Sport; Doping; Mass spectrometry; GW501516; Exactive; Orbitrap; Gene doping

向作者/读者索取更多资源

Since January 2009, the list of prohibited substances and methods of doping as established by the World Anti-Doping Agency includes new therapeutics such as the peroxisome-proliferator-activated receptor (PPAR)-delta agonist GW1516, which is categorized as a gene doping substance. GW1516 has completed phase II and IV clinical trials regarding dyslipidemia and the regulation of the lipoprotein transport in metabolic syndrome conditions; however, its potential to also improve athletic performance due to the upregulation of genes associated with oxidative metabolism and a modified substrate preference that shifted from carbohydrate to lipid consumption has led to a ban of this compound in elite sport. In a recent report, two presumably mono-oxygenated and bisoxygenated urinary metabolites of GW1516 were presented, which could serve as target analytes for doping control purposes after full characterization. Hence, in the present study, phase I metabolism was simulated by in vitro assays employing human liver microsomal fractions yielding the same oxygenation products, followed by chemical synthesis of the assumed structures of the two abundant metabolic reaction products. These allowed the identification and characterization of mono-oxygenated and bisoxygenated metabolites (sulfoxide and sulfone, respectively) as supported by high-resolution/high-accuracy mass spectrometry with higher-energy collision-induced dissociation, tandem mass spectrometry, and nuclear magnetic resonance spectroscopy. Since urine samples have been the preferred matrix for doping control purposes, a method to detect the new target GW1516 in sports drug testing samples was developed in accordance to conventional screening procedures based on enzymatic hydrolysis and liquid-liquid extraction followed by liquid chromatography, electrospray ionization, and tandem mass spectrometry. Validation was performed for specificity, limit of detection (0.1 ng/ml), recovery (72%), intraday and interday precisions (7.7-15.1%), and ion suppression/enhancement effects (<10%).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据