4.6 Article

Functional imaging of cerebrovascular activities in small animals using high-resolution photoacoustic tomography

期刊

MEDICAL PHYSICS
卷 34, 期 8, 页码 3294-3301

出版社

WILEY
DOI: 10.1118/1.2757088

关键词

photoacoustic imaging; photoacoustic signal; brain vascular; traumatic lesion; drug stimulation

向作者/读者索取更多资源

Photoacoustic imaging (PAI) is a noninvasive, nonionizing modality based on the differences in light absorption of various biological tissues. PAI utilizes the endogenous contrast characteristics of traditional optical imaging, while benefiting from high spatial resolution of the ultrasound imaging. A PAI system was developed to reconstruct the two-dimensional cross section image and to visualize the cerebrovascular activities of mouse in vivo. The spatial resolution of the PAI system was determined to be 0.110 mm by a two-point-source phantom with the Rayleigh criterion. The potential applications of the system were clearly demonstrated by successfully mapping a traumatic lesion in the mouse brain cerebral cortex, by its ability to monitor physiological changes in the brain due to carotid ligation and drug stimulation, and two-dimensional sliced images of a traumatic mouse brain at different depths were also provided. Our experimental results indicate that PAI has the potential for studying of traumatic brain injury and physiological functions of the brain. (c) 2007 American Association of Physicists in Medicine.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据